Alpha Tech Pet, Inc. - Product Detail Binder (January 2013)
immediately switched to ON, and the air flow rate recorded. The flow pump rate through the impingers was 2.3 L/min for all experiments.
Figure 3: KennelSol ® APS ClO 2
sachets suspended from ceiling vent
Results Twenty-one treatment experiments with KennelSol ® APS Room “Shock” Deodorizer were conducted in a two-month span. The individual data points are referenced in the Appendix (see Table 2). Average ClO 2 levels in the room air space, presented as parts-per-million-by-volume (ppmv), are displayed in Table 1. This data is presented in graphical form in Figure 4. The theoretical ClO 2 levels were calculated assuming all ClO 2 produced by the sachets accumulate in the room air and is not consumed. The ClO 2 generation expected of one sachet was determined by suspending a sachet over 10% KI solution in an enclosed glass container, placing the container in an unlit cabinet and analyzing via titration at 1-hour intervals for four hours. Theoretical and actual ClO 2 levels are presented in Figure 5.
Table 1: Average ClO 2
levels (ppmv)
No. Sachets
Time (hr)
1
2
3
4
1 2 3 4
0.07 0.02 0.05 0.01 0.03 0.02 0.02 0.01 0.11 0.08 0.10 0.08 0.05 0.04 0.04 0.02 0.11 0.07 0.10 0.07 0.05 0.03 0.04 0.02 0.16 0.05 0.08 0.04 0.03 0.03 0.03 0.03
Figure 4
ClO 2
Gas Levels in Area Treated with KennelSol APS Product
0 0.02 0.04 0.06 0.08 0.1 0.12 0.14 0.16 0.18
1 Sachet 2 Sachets 3 Sachets 4 Sachets OSHA limit
ppmv ClO2
0
1
2
3
4
5
Time (hr)